• Stepper drive

Stepper drive

Description

JMS Automation is the dealer of Stepper drive in Coimbatore. For details contact +91 82709 02623.

SEA2M44

Features

  • High performance, low noise, affordable price, high speed and torque, excellent stability
  • Single / dual pulse input
  • 16 selections of uniform angle and constant torque subdivisions, the max resolution up to 40000 steps/rev
  • Adoption of 4-wires-control circuit greatly reduces noise and increases the rotation stability
  • The max response frequency up to 300KHz
  • Once the pulse stops for more than 100ms, the coil current will be halved automatically, to prevent the overheating
  • Bipolar constant current chopper control improves the output speed and power of the motor
  • Photoelectric-isolated signal I / O
  • Current range:0.1A~4.5A
  • Single power input, voltage range: DC12~40V( the optimal voltage is DC36V )
  • Signal source voltage: DC3.3~28V
  • Error protection:A Open phase protection   Overheating A Overcurrent   Low voltage
  • Size:117mmx75.7mmx33mm, Net weight:0.27kg

Description

SEA2M44 is a microstep motor driver with uniform angle and constant torque subdivisions, voltage range is DC12V~40V ( the optimal voltage is DC36V ), single power supply. It matches 2 phase hybrid stepper motors which rated current under 4.5A, external diameter 56m m~60mm, and outlets 4, 6 or 8outlets.

Bipolar constant current chopper control makes the motor run smoothly with lower noise and higher stability; The increase of the voltage greatly improves the drive capability and speed. The coil current will be halved automatically onece the pulse stops for more than 100ms, it reduces the heat of driver by 50%, reduces the heat of motor as well. Users can choose low speed high subdivision which up to 40000 steps / rev, it improves the precision, reduces the vibration and noise.

Applications

Carpentry engracing machine, Laser engraving machine, Labelling machine, Die bonder, Inkjrt printer, Embroiderer, Dispenser, BGA repair machine, Laminating machine Wire-stripping machine, Winding machine, Hot-press machine, PCB drilling machine, Non-standard equipment, XYZ gauge, Connctors assemble machine, Medical equipments, Semiconductor Equipment, Blast furnace, etc.

Running Current Setting

Im (A)

1.0

1.1

1.3

1.5

1.8

2.0

2.3

2.5

2.8

3.0

3.2

3.5

3.8

4.0

4.2

4.5

D1

OFF

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

ON

ON

D2

OFF

OFF

ON

OFF

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON

ON

D3

OFF

OFF

OFF

ON

OFF

OFF

ON

ON

ON

ON

OFF

OFF

ON

ON

OFF

ON

D4

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

ON

ON

Microstep Setting List

 

Pulse/rev

200

400

800

1000

1600

2000

3200

4000

5000

6400

8000

10000

12800

20000

25600

40000

D5

ON

OFF

ON

ON

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

D6

ON

ON

OFF

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

D7

ON

ON

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

D8

ON

ON

ON

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

D9

ON: Double Pulse, PU is Clockwise pulse, DR is Counter Clockwise stepper pulse signal. OFF: Single Pulse, PU is pulse signal, DR is Direction control stepper signal.

Self detect switch (OFF: accept external pulse signal; ON: driver internal send 7.5kHz pulse, rotate speed can be controlled by

D5~D8.

D10

Installation dimensions

Driver Connection

Pin Functions

Mark

Function

Instruction

Power on, the green indicator normally on.

Overcurrent, phase open circuit, overtension, low voltage, the red indicator flashes.

POWER

Power indicator

O.H

Fault indecator

MF-

Motor free signal

When the low electrical level is valid, it cuts off the motor current, the driver stops working and motor will be in a free state.

MF+

Input signal positive side

Connects +3.3V~+28V pulse signal power.

DR-

Direction control signal

For changing the direction,input resistance is 220 Ω. Requires: low level +0V~

+0.5V, high level+4V~+5V, pulse width >2.5 μs

DR+

Input signal positive side

Connects +3.3V~+28V pulse signal power.

 

PU-

 

Pulse signal

When the falling edge is valid, the motor moves a step as the pulse become lower, input resistance is 220Ω. Requires: low level +0V~+0.5V, high level +4V

~+5V, pulse width >2.5 μs.

PU+

Input signal positive side

Connects +3.3V~+28V pulse signal power.

+V

Power+

DC12~40V ( the optimal voltage is DC36V )

-V

Power-

-B¸+B

Connect to the motor

Please refer to the motor connections.

Alarm functions

  • 1 Green 1 Red   Alternately flashes,Overcurrent;
  • 1 Green 2 Red   Alternately flashes,Phase open circuit;
  • 1 Green 3 Red   Alternately flashes,Overvoltage;
  • 1 Green 4 Red   Alternately flashes, Low voltage;
  • 1 Green 5 Red   Alternately flashes,Other faults;

The driver will lose self-locking function when the above alarms start,please clear faults and re-up electricity,the driver goes back to normal when the power green indicator normally on.

 

?Attention:The driver can't be protective when connects the wire inversely or wrong,please confirm the connections before electrify it,otherwise the fuse inside may be burnout.

 

SEA2M60M

Features

  • High performance, low noise, affordable price, high speed and torque, excellent stability
  • Single / dual pulse input
  • 16 selections of uniform angle and constant torque subdivisions, the max resolution up to 40000 steps/rev
  • Adoption of 4-wires-control circuit greatly reduces noise and increases the rotation stability
  • The max response frequency up to 300KHz
  • Once the pulse stops for more than 100ms, the coil current will be halved automatically, to prevent the overheating
  • Bipolar constant current chopper control improves the output speed and power of the motor
  • Photoelectric-isolated signal I / O
  • Current range:0.1A~6.5A
  • Single power input, voltage range: AC16~90V( the optimal voltage is AC60V )
  • Signal source voltage: DC3.3~28V
  • Error protection:A Open phase protection   Overheating A Overcurrent   Low voltage
  • Size:117mmx75.7mmx33mm, Net weight:0.27kg

    Applications                                                                                                               

    Carpentry engracing machine, Laser engraving machine, Labelling machine, Die bonder, Inkjrt printer, Embroiderer, Dispenser, BGA repair machine, Laminating machine Wire-stripping machine, Winding machine, Hot-press machine, PCB drilling machine, Non-standard equipment, XYZ gauge, Connctors assemble machine, Medical equipments, Semiconductor Equipment, Blast furnace, etc.

  • Running Current Setting

  • Im (A)

    2.8

    3.0

    3.2

    3.5

    3.8

    4.0

    4.2

    4.5

    4.8

    5.0

    5.2

    5.5

    5.8

    6.0

    6.2

    6.5

    D1

    OFF

    ON

    OFF

    OFF

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    ON

    ON

    D2

    OFF

    OFF

    ON

    OFF

    OFF

    ON

    OFF

    ON

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    ON

    D3

    OFF

    OFF

    OFF

    ON

    OFF

    OFF

    ON

    ON

    ON

    ON

    OFF

    OFF

    ON

    ON

    OFF

    ON

    D4

    OFF

    OFF

    OFF

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    ON

    OFF

    ON

    ON

    ON

    Microstep Setting List
  • Pulse/rev

    200

    400

    800

    1000

    1600

    2000

    3200

    4000

    5000

    6400

    8000

    10000

    12800

    20000

    25600

    40000

    D5

    ON

    OFF

    ON

    ON

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    OFF

    OFF

    D6

    ON

    ON

    OFF

    ON

    ON

    OFF

    ON

    OFF

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    OFF

    D7

    ON

    ON

    ON

    OFF

    ON

    ON

    OFF

    OFF

    OFF

    OFF

    ON

    ON

    OFF

    OFF

    ON

    OFF

    D8

    ON

    ON

    ON

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    OFF

    ON

    OFF

    OFF

    OFF

    D9

    ON: Double Pulse, PU is Clockwise pulse, DR is Counter Clockwise stepper pulse signal. OFF: Single Pulse, PU is pulse signal, DR is Direction control stepper signal.

    Self detect switch (OFF: accept external pulse signal; ON: driver internal send 7.5kHz pulse, rotate speed can be controlled by

    D5~D8.

    D10

    Installation dimensions                                                                                      Driver Connection

  •  

                                
  •  

    Pin Functions

  •  

    Mark

    Function

    Instruction

    Power on, the green indicator normally on.

    Overcurrent, phase open circuit, overtension, low voltage, the red indicator flashes.

    POWER

    Power indicator

    O.H

    Fault indecator

    PU+

    Input signal positive side

    Connects +3.3V~+28V pulse signal power.

     

    PU-

     

    Pulse signal

    When the falling edge is valid, the motor moves a step as the pulse become lower, input resistance is 220Ω. Requires: low level +0V~+0.5V, high level +4V

    ~+5V, pulse width >2.5 μs.

    DR+

    Input signal positive side

    Connects +3.3V~+28V pulse signal power.

    DR-

    Direction control signal

    For changing the direction,input resistance is 220 Ω. Requires: low level +0V~

    +0.5V, high level+4V~+5V, pulse width >2.5 μs

    MF+

    Input signal positive side

    Connects +3.3V~+28V pulse signal power.

    MF-

    Motor free signal

    When the low electrical level is valid, it cuts off the motor current, the driver stops working and motor will be in a free state.

    +V

    Power+

    AC16~90V ( the optimal voltage is AC60V )

    -V

    Power-

    -B¸+B

    Connect to the motor

    Please refer to the motor connections.

     

     Alarm functions

  • 1 Green 1 Red   Alternately flashes,Overcurrent;
  • 1 Green 2 Red   Alternately flashes,Phase open circuit;
  • 1 Green 3 Red   Alternately flashes,Overvoltage;
  • 1 Green 4 Red   Alternately flashes, Low voltage;
  • 1 Green 5 Red   Alternately flashes,Other faults;
  • The driver will lose self-locking function when the above alarms start,please clear faults and re-up electricity,the driver goes back to normal when the power green indicator normally on.

     

    ?Attention:The driver can't be protective when connects the wire inversely or wrong,please confirm the connections before electrify it,otherwise the fuse inside may be burnout.